Mitsubishi Electric MELSERVO MR-J3 Repair
The Mitsubishi Electric MELSERVO MR-J3 is a motion-control drive used to regulate servo motor speed, torque, and position in high-precision industrial machinery.
| Brand | Mitsubishi Electric |
| Equipment | MR-J3-10BS1 |
| Equipment Category | MELSERVO MR-J3 |
| Industry | Plastics |
| Fault Reported |
|
| Repair Turnaround Time | Typical reference: 3–6 working days |
The Challenge
Loss of the servo axis stopped accurate machine movement and prevented normal production cycles.
Diagnosis
- The DC bus, IGBT stage, driver board, current feedback, encoder interface, control power, communication circuitry, and cooling system were evaluated.
Our Solution
- Failed electronic components were replaced where required, PCB defects and solder joints were restored, cooling was serviced, and the drive was tested with compatible feedback or motor simulation.
Testing Performed
- Power-up test; DC-bus test; power-stage test; encoder/feedback test; communication test; axis enable test; thermal burn-in.
Final Result
The reference repair process restores normal functional operation after the unit passes the defined electrical, communication, motion, or load checks applicable to the equipment.
Common Fault Codes & Causes
- AL.10 – Undervoltage: Control/main power voltage drop, supply interruption or input circuit issue.
- AL.12 – Memory error 1 (RAM): Internal memory/control board fault.
- AL.13 – Clock error: Internal clock/control electronics fault.
- AL.15 – Memory error 2 (EEP-ROM): EEPROM/control board fault.
- AL.16 – Encoder error 1: Encoder communication/cable/connector or encoder fault at power-up.
- AL.17 – Board error: Internal board/control electronics fault.
- AL.20 – Encoder error 2: Encoder communication or feedback fault during operation.
- AL.21 – Encoder error 3: Encoder/feedback data error during operation.
- AL.24 – Main circuit error: Power circuit, DC bus or power-stage fault.
- AL.50 – Overload 1: Excessive continuous motor load, jam or thermal overload.
Preventive Maintenance
- Inspect motor and feedback cables, maintain cabinet cooling, prevent overloads, check grounding, and investigate repeated fault codes before continued operation.
Related Services
- Industrial Electronics Repair; Servo Motor Repair; Servo Drive Repair; PLC/HMI/VFD Repair; PCB Repair
Need Professional Repair?
Mitsubishi Electric MELSERVO MR-J3 repair in Egypt for AL.10, AL.12, AL.13 and other common faults. Professional diagnosis, repair and testing by EISAC Autom...
Contact Our Engineering Team TodayKEEPING INDUSTRY MOVING